    "data": {
        "id": 1310,
        "sku": "5CPQ6221",
        "name": "Gun - Stainless Steel Shut-Off",
        "type": "simple",
        "variations_count": 0,
        "manufacturer": "Cat Pumps",
        "product_url": "https://www.catpumps.com/products/pumps/5cp-plunger-pump-5cpq6221",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 39,
            "name": "Plunger Pumps"
        },
        "categories": [
            {
                "id": 39,
                "name": "Plunger Pumps"
            },
            {
                "id": 42,
                "name": "Stainless Steel Pumps"
            },
            {
                "id": 52,
                "name": "Belt Drive Pumps"
            }
        ],
        "series": null,
        "specifications": {
            "Max Flow": "6 gpm / 22.7 lpm",
            "Max Pressure": "2000",
            "Inlet Port Size": "1/2\" NPT(F)",
            "Discharge Port Size": "3/8\" NPT(F)",
            "RPM": "1400",
            "Drive Type(s)": "Belt, Clutch, Flexible Coupling and Bellhousing",
            "Material": "316 Stainless Steel"
        },
        "images": [
            {
                "src": "https://catpumps.weareindata.com/downloaded_assets/catpumps/images/92/3a/923ae4c5110b7850cd17e83df1382bfc3044b4b0aa7713de546526e5792628e0.jpg",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/images/92/3a/923ae4c5110b7850cd17e83df1382bfc3044b4b0aa7713de546526e5792628e0.jpg",
                "local_path": "catpumps/images/92/3a/923ae4c5110b7850cd17e83df1382bfc3044b4b0aa7713de546526e5792628e0.jpg",
                "original_url": "https://www.catpumps.com/sites/default/files/2019-12/5CPQ6221_287_1.jpg",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "5CPQ6221, 5CPQ6241CS, 5CPQ6251, 5CPQ6271CSS, 5CPQ6281CSS Data Sheet",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/80/02/8002f16ef7a0a05848bba784520ff2c54c34574d2f59a6993d44e4a9d5191d2a.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/80/02/8002f16ef7a0a05848bba784520ff2c54c34574d2f59a6993d44e4a9d5191d2a.pdf"
            },
            {
                "text": "CP Stainless Steel Plunger Service Manual",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/67/7a/677a2a932f4f115b6dbc91026dfed5f9ccc9f8430fc644919835d0d1e279850a.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/67/7a/677a2a932f4f115b6dbc91026dfed5f9ccc9f8430fc644919835d0d1e279850a.pdf"
            },
            {
                "text": "Tech Bulletin 122 - Design Changes For 2SF and 5CP Stainless Steel Pumps",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/20/4c/204c4d47ff0f1540799a416e85a40feeebadb27c484c9e62ae947006b3c3f27f.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/20/4c/204c4d47ff0f1540799a416e85a40feeebadb27c484c9e62ae947006b3c3f27f.pdf"
            },
            {
                "text": "Tech Bulletin 002 - Inlet Pressure vs. Water Temperature",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/4c/c5/4cc585c3566fa461f1bb1839a99cd396d77043a3dffd2269e7aaf5731d5f19d8.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/4c/c5/4cc585c3566fa461f1bb1839a99cd396d77043a3dffd2269e7aaf5731d5f19d8.pdf"
            },
            {
                "text": "Tech Bulletin 034 - Servicing Crankcase Section - Ball Bearing Models",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/35/9d/359d1ccfa6f9053cc4d44d167f17cfce56f0f8a03eaf67e19cb8f761f81555c4.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/35/9d/359d1ccfa6f9053cc4d44d167f17cfce56f0f8a03eaf67e19cb8f761f81555c4.pdf"
            },
            {
                "text": "Tech Bulletin 036 - Identifying Your Pump",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/46/34/46348c6ccae7f8ac70f86752c13562117778951b10f25cb25f911c03228f9c05.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/46/34/46348c6ccae7f8ac70f86752c13562117778951b10f25cb25f911c03228f9c05.pdf"
            },
            {
                "text": "Tech Bulletin 043 - Servicing the Low and High Pressure Seals",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/7f/41/7f411cc0b3dc338d654ef611d5f4e8007a5fe825825eacc9440640db1f670419.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/7f/41/7f411cc0b3dc338d654ef611d5f4e8007a5fe825825eacc9440640db1f670419.pdf"
            },
            {
                "text": "Tech Bulletin 074 - Torque Chart",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/38/64/386427f13eafbe3367da343707247bef17cf14bd34bdd9f0a02394953139b856.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/38/64/386427f13eafbe3367da343707247bef17cf14bd34bdd9f0a02394953139b856.pdf"
            },
            {
                "text": "Tech Bulletin 083 - Winterizing a Pump",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/b9/ec/b9ecea19a307f6e28e1320103b41423ec796be51da3a4a68fe37a6d07d619ffb.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/b9/ec/b9ecea19a307f6e28e1320103b41423ec796be51da3a4a68fe37a6d07d619ffb.pdf"
            },
            {
                "text": "Tech Bulletin 088 - 6-Bolt SS Manifold",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/7a/51/7a51016ef6d38c8e826cf87219338ddabc0a7dbff6da1b25c7096d811cc7c843.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/7a/51/7a51016ef6d38c8e826cf87219338ddabc0a7dbff6da1b25c7096d811cc7c843.pdf"
            },
            {
                "text": "Tech Bulletin 095 - Galling Prevention",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/5a/1b/5a1bfb9833dc812da9cfc0d9f15886f3dfaa0b0f92fd225b34c3e6a9e72b2ca8.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/5a/1b/5a1bfb9833dc812da9cfc0d9f15886f3dfaa0b0f92fd225b34c3e6a9e72b2ca8.pdf"
            },
            {
                "text": "Tech Bulletin 134 - Piston and Plunger Pump Crankcase Capacities",
                "type": "pdf",
                "url": "https://catpumps.weareindata.com/downloaded_assets/catpumps/pdfs/5d/77/5d77a7d2654c085eace2cadcae149336e893f541a16f5f759b1aea0891c9eadf.pdf",
                "original_url": null,
                "local_path": "catpumps/pdfs/5d/77/5d77a7d2654c085eace2cadcae149336e893f541a16f5f759b1aea0891c9eadf.pdf"
            },
            {
                "text": "5CP6221.STEP",
                "type": "cad",
                "url": null,
                "original_url": null,
                "local_path": null
            },
            {
                "text": "5CP6221.DWG",
                "type": "cad",
                "url": null,
                "original_url": null,
                "local_path": null
            }
        ],
        "custom_fields": {
            "model": "5CPQ6221",
            "product_type": "pump",
            "status": "",
            "replaced_by": "",
            "max_psi": "2000",
            "max_bar": "138",
            "shaft": null,
            "min_pressure": null
        },
        "description": "This triplex (three plunger rods) positive displacement, reciprocating plunger pump is constructed with 316 stainless steel manifolds, 316 stainless steel valve assemblies, solid ceramic plungers and standard NBR (Buna-N) seals and O-rings.\n\nCat Pumps “Q” pump models reduce sound levels by -6 dBa (decibels). With “Q” model pumps and other noise reduction measures, equipment builders can supply quiet, pleasing equipment to their customers.",
        "created_at": "2026-08-23 08:08:45",
        "variations": []
    }
}